Effective nitrogen blowdown evaporation balances gas flow and heat to remove solvent quickly without degrading delicate samples. Here are some tips to optimise your blowdown evaporation

Effective blowdown evaporation starts with proper gas flow. Optimal flow rate depends on size of the gas delivery needles used. Small samples can be efficiently concentrated with 19 gauge needles, while wider tubes benefit from the higher flow allowed by larger needles.

Whichever needles you use, at a proper flow rate, the gas stream should be strong enough to create a visible dimple in the surface of the sample while still minimising splashing. This ensures that the gas stream disrupts and removes the solvent vapor layer above the sample, allowing more solvent to evaporate.

A bath temperature of 2-3°C below the boiling point of the solvent is ideal to promote efficient evaporation without subjecting the sample to the harsh conditions of boiling. For heat-sensitive samples, a bath temperature of around 30°C to 40°C will help to combat the cooling effect of evaporation.

There are several gas source options for blowdown evaporation, including nitrogen cylinders, lab air or nitrogen, or a nitrogen generator. Nitrogen purity requirements are determined by the chemist—even clean air can work for evaporation. The most important consideration is that the gas be dry. Most nitrogen gas typically has a low moisture content already, but compressed air needs to be dried to promote efficient evaporation.

Remember, evaporation is fastest when the gas stream successfully disrupts the vapor layer above the sample. The closer the gas delivery needles are to the surface of the sample, the less gas will be required for effective evaporation. To conserve nitrogen, always keep needles close to the sample’s surface.

Cleaning needles after use, especially if any solvent has splashed on them, is the best way to prevent contamination between samples. Regular cleaning will also greatly prolong the life of the needles. For a lower maintenance solution, try using disposable glass pipettes instead for nitrogen delivery.

For further information please click here.

The role of aptamers in cancer therapy There are two major applications for aptamers in cancer therapy. Aptamers can be used as antagonists by targeting a...

What type of label do you require for testing? Specialist laboratory labels are essential for various sectors, such as environmental, agricultural, biotec...

Biotool Switzerland announce the ProfiClave PCX - a new space-saving system that simplifies culture media preparation and speeds up the process. Designed...

Automatic, modular system for SLS and DLS The BI-200SM goniometer from Testa Analytical Solutions eK has been designed to make it the finest instrument av...

In This Edition Chromatography - Achiral Supercritical Fluid Chromatography (SFC) for the Purification of Pharmaceuticals - Equivalent GC systems performance for regulatory method compliance...

ChemBio Finland 2022 - NEW DATES

International Labmate Limited Oak Court Business Centre Sandridge Park, Porters Wood St Albans Hertfordshire AL3 6PH United Kingdom

T +44 (0)1727 858 840 F +44 (0)1727 840 310 E info@labmate-online.com

Copyright © 2022 Labmate Online. All rights reserved.